BBWLJ - GC-250 ACCELERATOR, V00605-26991
- MSDS: BBWLJ
- Manufacturer: GOAL CHEMICAL SEALANTS CORP
- Product Name: GC-250 ACCELERATOR, V00605-26991
- National Stock Number: 8040-00F006764
Product Identification
Product ID:GC-250 ACCELERATOR, V00605-26991
MSDS Date:01/01/1987
FSC:8040
NIIN:00F006764
MSDS Number: BBWLJ
Responsible Party
Emergency Phone: (213) 269-0461
Cage: 04011
Contractor
Telephone: 213-269-0461
Cage: 04011
Ingredients
LEAD PEROXIDE (LEAD DIOXIDE), (OSHA PEL FROM 29CFR
CAS: 1309-60-0
RTECS: OG0700000
OSHA PEL 0.05 MG/M3 (PB)
ACGIH TLV: 0.15 MG/M3(PB); 8990
First Aid
First Aid:INGESTION: CRAMPING IN LOWER ABDOMEN. CONSULT PHYSICIAN.
SKIN: WASH WITH SOAP & WATER. EYES: FLUSH WITH WATER AT LEAST 15
MINUTES. CONSULT PHYSICIAN.
Fire Fighting
Flash Point:345F TCC
Extinguishing Media:WATER, CO2, FOAM, DRY CHEMICAL
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:NONE
Accidental Release
Spill Release Procedures:SCRAPE UP & STORE IN NONFLAMMABLE CONTAINER.
Handling
Handling and Storage Precautions:AVOID INGESTION OF MATERIAL, WASH
THOROUGHLY AFTER HANDLING BEFORE SMOKING OR EATING. STORE <8.
Other Precautions:FOR MANUFACTURING USE ONLY.
Exposure Controls
Protective Gloves:NEOPRENE/BUNA-N
Eye Protection:SAFETY GLASSES
Other Protective Equipment:PROTECTIVE OUTER CLOTHING AS REQUIRED TO
PREV. CONTAMINATED.
Supplemental Safety and Health
MSDS DATED: 3/31/86.
Chemical Properties
Boiling Pt:B.P. Text:644F
Spec Gravity:2.9
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BROWN PASTE OILY ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:TEMPERATURE IN EXCESS OF 200C
Hazardous Decomposition Products:CO, CO2, SOOT
Disposal
Waste Disposal Methods:REACT WITH BASE AND DISPOSE AS INERT MATERIAL,
OR RETURN TO SMELTER FOR RECLAMATION.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.